WaterSense® Checklist
INDOOR WATER EFFICIENCY CRITERIA
Project
Builder
Date
Leaks
A pressure-loss test on all water supply lines detected no leaks
Yes/Pass/True
No/Fail/False
NA
See Note
There are no visible water leaks from the hot water delivery system
Yes/Pass/True
No/Fail/False
NA
See Note
There are no visible water leaks from toilets or urinals
Yes/Pass/True
No/Fail/False
NA
See Note
There are no visible water leaks from bathroom faucets
Yes/Pass/True
No/Fail/False
NA
See Note
There are no visible water leaks from kitchen faucets
Yes/Pass/True
No/Fail/False
NA
See Note
There are no visible water leaks from showerheads
Yes/Pass/True
No/Fail/False
NA
See Note
There are no visible water leaks from other fixtures or appliances
Yes/Pass/True
No/Fail/False
NA
See Note
Service Pressure
Single-family: The pressure tank is installed and is set to 60 psi or less, OR
Yes/Pass/True
No/Fail/False
NA
See Note
Single-family: A Pressure-Regulating Valve (PRV) is installed upstream of fixtures and pressure is set to 60 psi or less, OR
Yes/Pass/True
No/Fail/False
NA
See Note
Single-family: A pressure test shows pressure at 60 psi or less and homebuilder has written documentation from the water supplier that pressure is 60 psi or less
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
Multi-family:A pressure test shows the pressure at 60 psi or less
Yes/Pass/True
No/Fail/False
NA
See Note
Hot Water Delivery
The hot water delivery system stores 0.5 gallons (1.9 liters) or less in any piping or maifold between the hot water source and any hot water fixture
Yes/Pass/True
No/Fail/False
NA
See Note
The hot water delivery system is
not
based solely on a timer and/or a temperature sensor
Yes/Pass/True
No/Fail/False
NA
See Note
The system is a
demand-initiated
recirculating system
Yes/Pass/True
No/Fail/False
NA
See Note
When the hot water delivery system is engaged, there is a 10°F temperature increase before 0.6 gallons (2.3 liters) has been disbursed
Yes/Pass/True
No/Fail/False
NA
See Note
Toilets
All toilets are WaterSense® labeled
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
Flushing Urinals
All flushing urinals are WaterSense® labeled
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
Bathroom Sink Faucets
All bathroom sink faucets are WaterSense® labeled
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
The bathroom sink faucet measured flow rate is a maximum of 1.5 gpm (Flow test maximum: 0.25 gallons)
Yes/Pass/True
No/Fail/False
NA
See Note
Kitchen Sink Faucets
The kitchen sink faucet measured flow rate is a maximum of 2.2 gpm (Flow test maximum: 0.4 gallons)
Yes/Pass/True
No/Fail/False
NA
See Note
Showerheads
All showerheads are WaterSense® labeled
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
The showerhead measured flow rate is a maximum 2.0 gpm water per shower compartment less than 2,160 square inches (Flow test maximum: 0.35 gallons/compartment)
Yes/Pass/True
No/Fail/False
NA
See Note
There are separate controls for showerheads if the show compartment is greater than 2160 square inches
Yes/Pass/True
No/Fail/False
NA
See Note
Dishwasher
The dishwasher is ENERGY STAR® qualified
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
Clothes Washer
The clothes washer is ENERGY STAR® qualified
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
The clothes washer water factor is less than 6.0 gallons per cycle per cubic foot of capacity
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
Evaporative Cooling System
The evaporative cooling system is
not
a once-through or single pass cooling system
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
The evaporative cooling system is
not
a system with continuous blowdown or bleedoff
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
The evaporative cooling system is
not
a system with timer-only mediated blowdown management
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
The evaporative cooling system uses a maximum of 3.5 galons (13.3 liters) of water per ton-hour of cooling
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
The evaporative cooling system has a maximum of three (3) blowdowns in 24 hours
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
Blow-downs are controlled through conductivity or a basin temperature-based controller
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
Water Softener
Water softeners are Certified to NSF/ANSI Standard 44, including voluntary efficiency rating standards in Section 7
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
Drinking Water
Drinking water treatment systems are NSF/ANSI certified, with minimum efficiency rating of 85%
Yes/Pass/True
No/Fail/False
NA
See Note
Builder has and will provide the required documentation
Send to
Builder representative
Builder email
Copy to
Subcontractor
Subcontractor representative
Subcontractor email
Send Inspection Report
My Cart
0
Discount
Add Coupon Code
Apply
Subtotal
Total Installment Payments
Bundle Discount
Checkout
0